Call Us
+86 136 6007 9809
120° Countersunk Closed-End Stainless Steel Blind Rivets
JUXIN FASTENERS supplies closed-end blind rivets with 120° countersunk heads, 300-series stainless steel bodies and stainless steel pull mandrels for OEM sheet-metal assemblies requiring one-sided installation and a flush-head fastening design.
The closed-end rivet body reduces potential leakage paths through the rivet, while the 120° countersunk head fits a matching countersink in the accessible panel. Actual sealing performance depends on hole geometry, panel contact, installation quality and any additional sealing requirements.
The exact body and mandrel grades, grip ranges, mechanical strength, mandrel retention and corrosion performance must be verified from the approved product specification.
Product Specification
120° Countersunk Closed-End Stainless Steel Blind Rivets for OEM Sealing and Flush-Mount Assemblies
Product Overview
JUXIN FASTENERS supplies 120° countersunk closed-end stainless steel blind rivets for OEM sheet-metal fabrication, industrial equipment enclosures, vehicle components and other permanent fastening applications requiring one-sided installation.
This product features a 300-series stainless steel rivet body, a stainless steel pull mandrel and a 120-degree countersunk head.
The closed-end construction is designed to reduce potential leakage through the rivet body, while the countersunk head allows a flush or near-flush installation when used with a correctly prepared mating countersink.
Unlike conventional open-end blind rivets, closed-end designs use a sealed blind-end rivet body to limit the through-body passage of moisture, air and contaminants.
However, the closed-end construction alone does not guarantee that the entire installed joint is watertight or airtight.
The actual sealing performance depends on rivet geometry, hole tolerances, countersink fit, mating surfaces, installation quality and the required environmental conditions.
Product Identification and Technical Specifications
| Item | Specification |
|---|---|
| Product Name | 120° Countersunk Closed-End Stainless Steel Blind Rivets |
| Product Category | Closed-End Blind Rivets |
| Rivet Type | Closed-End / Sealed Break-Mandrel Blind Rivet |
| Rivet Body Material | 300-Series Stainless Steel |
| Pull Mandrel Material | Stainless Steel |
| Head Style | 120° Countersunk Head |
| Head Function | Flush-Mount Installation |
| Blind-End Construction | Closed-End |
| Installation Method | One-Sided Mechanical Blind Riveting |
| Body Stainless Steel Grade | Exact grade to be confirmed |
| Mandrel Stainless Steel Grade | To be confirmed |
| Material Condition | According to approved specification |
| Grip Range | According to selected part number |
| Mounting-Hole Diameter | According to approved drawing |
| Countersink Angle | 120° nominal |
| Shear and Tensile Performance | Verified product data required |
| Mandrel Retention | Product-specific verification required |
| Sealing Performance | Joint-specific verification required |
| Surface Finish | According to approved specification |
| Technical Reference | Original PDF/CAD, pages 107–108 |
Key Product Features
300-series stainless steel rivet body
Stainless steel pull mandrel
Closed-end blind rivet construction
120° countersunk head
Flush-mount fastening capability
One-sided mechanical installation
Reduced potential leakage through the rivet body
Defined grip range for controlled material stack-up
Stainless steel material options for corrosion-sensitive assemblies
Permanent mechanical fastening
Compatibility with approved riveting tools
Drawing-based OEM technical specifications
Actual mechanical strength, sealing effectiveness and corrosion resistance must be verified for the selected part number.
Product Dimensions and Engineering Data
| Parameter | Required Specification |
|---|---|
| Nominal Rivet Diameter | Refer to original PDF/CAD |
| Rivet Body Length | Refer to original PDF/CAD |
| Countersunk Head Diameter | According to approved drawing |
| Countersunk Head Height | According to approved drawing |
| Countersink Angle | 120° nominal |
| Mandrel Diameter | According to approved drawing |
| Minimum Grip Thickness | According to selected part |
| Maximum Grip Thickness | According to selected part |
| Recommended Hole Diameter | According to approved drawing |
| Hole Diameter Tolerance | According to approved drawing |
| Countersink Diameter | According to approved drawing |
| Countersink Depth | According to approved drawing |
| Blind-Side Clearance | According to installed rivet geometry |
| Shear Load Capacity | Verified test data required |
| Tensile Load Capacity | Verified test data required |
| Sealing Performance | According to approved test requirements |
| Installation Tooling | According to selected rivet |
Technical Documentation
For exact product dimensions, available sizes, head geometry and detailed technical information, refer to the original JUXIN product PDF/CAD, pages 107–108.
Customer-specific dimensions and configurations may be submitted for engineering feasibility review.
Engineering Solution 1 — What Is a Closed-End Blind Rivet?
A closed-end blind rivet uses a rivet body with a closed blind end.
During installation, the pull mandrel deforms the rivet body to form the retaining portion on the inaccessible side of the joint.
The closed-end construction differs from an open-end blind rivet, where a potential passage through the rivet body may remain.
Closed-end designs are commonly considered where the assembly requires improved resistance to moisture, air or contaminant passage through the fastener.
However, leakage may still occur around the mounting hole, beneath the head or between the connected panels.
The complete installed joint must therefore be evaluated.
Engineering Solution 2 — 120° Countersunk Head vs. Dome Head
The head style is a critical difference between this product and conventional dome head blind rivets.
| Engineering Factor | 120° Countersunk Head | Dome Head |
|---|---|---|
| Head Geometry | Conical underside | Protruding rounded head |
| Installation Surface | Prepared countersink required | Generally flat seating surface |
| Installed Appearance | Flush or near-flush | Protruding |
| Head Bearing | Depends on countersink fit | Depends on head contact area |
| Panel Preparation | Countersinking required | Usually no countersink |
| Thin Panel Consideration | Remaining panel thickness is important | Head-side bearing is important |
| Interchangeability | Requires drawing review | Requires drawing review |
A 120° countersunk rivet must not be installed into a countersink prepared for a different head angle without engineering verification.
Engineering Solution 3 — Countersink Geometry and Flush-Mount Design
A properly designed countersink supports the rivet head and allows the required installed surface profile.
Important dimensions include:
Countersink angle
Countersink major diameter
Countersink depth
Rivet head diameter
Rivet head height
Mounting-hole diameter
Panel thickness
Remaining material beneath the countersink
Excessive countersink depth may reduce the remaining panel thickness and weaken the joint.
Insufficient countersink depth may leave the rivet head protruding.
A mismatched angle may cause incomplete head seating and uneven contact pressure.
The countersink should be prepared according to the approved rivet and assembly drawings.
Engineering Solution 4 — Closed-End Sealing Mechanism
The closed-end rivet body helps limit leakage through the fastener itself.
This may be valuable in industrial enclosures and other applications where moisture or contamination is a concern.
However, the installed assembly contains multiple possible leakage paths:
Through the rivet body
Between the rivet body and mounting hole
Beneath the countersunk head
Between overlapping panels
Through adjacent gaps or damaged surfaces
A closed-end rivet primarily addresses the through-body leakage path.
Additional joint design measures may be required to control the other leakage paths.
Engineering Solution 5 — Water Resistance vs. Watertight Performance
The terms water-resistant, watertight and waterproof should not be used interchangeably.
A closed-end rivet may improve resistance to water passage through the rivet body.
A fully watertight joint requires verification of the complete assembly under defined conditions.
Relevant test parameters may include:
Water pressure
Exposure duration
Spray direction
Temperature
Joint orientation
Surface condition
Installation quality
No universal watertight pressure rating is claimed for this product.
Engineering Solution 6 — Air Leakage and Pressure Boundaries
Closed-end rivets may reduce potential air leakage through the fastener body.
However, they should not automatically be treated as airtight fasteners or pressure-rated components.
For applications involving air leakage limits, engineers should define:
Permissible leakage rate
Pressure differential
Test duration
Test medium
Operating temperature
Joint geometry
Inspection criteria
Pressure vessels, pressurized piping and regulated pressure boundaries require separate design and qualification.
Engineering Solution 7 — Stainless Steel Material Selection
The original product information specifies a 300-series stainless steel rivet body and stainless steel mandrel.
The 300 series includes several stainless steel grades with different corrosion and mechanical characteristics.
The description does not identify one exact grade.
Therefore, the following details should be confirmed:
Rivet body alloy
Mandrel alloy
Material condition
Mechanical properties
Corrosion requirements
Surface condition
Traceability requirements
The rivet body and mandrel may use different stainless steel grades to meet their respective forming and pulling requirements.
Engineering Solution 8 — Understanding 18-8 Stainless Steel
The term 18-8 stainless steel is commonly associated with austenitic stainless steels containing approximately 18% chromium and 8% nickel.
It is widely used in industrial fastener descriptions.
However, 18-8 is not an exact substitute for every 300-series stainless steel grade.
A material requirement such as AISI 304, AISI 305 or AISI 316 must be confirmed individually.
The original product information does not establish the exact JUXIN body or mandrel grade.
Engineering Solution 9 — Stainless Steel Corrosion Resistance
Stainless steel can provide useful corrosion resistance in suitable operating environments.
However, stainless steel is not immune to corrosion.
Potential concerns include:
Pitting corrosion
Crevice corrosion
Chloride exposure
Surface contamination
Galvanic corrosion
Chemical exposure
Closed-end geometry does not eliminate corrosion risk at the head, mounting hole or panel interface.
For outdoor or chemically exposed equipment, the stainless steel grades must be matched to the actual service environment.
No salt spray rating or corrosion service life is claimed without verified test data.
Engineering Solution 10 — Magnetic Behavior of Stainless Steel Rivets
Some 300-series stainless steel components may exhibit a degree of magnetic response after cold working.
Magnetic response alone is not a reliable method for identifying the exact stainless steel grade.
For applications requiring controlled magnetic properties, the requirement should be included in the engineering specification.
No nonmagnetic or magnetic performance guarantee is made without testing.
Engineering Solution 11 — Grip Range Selection
The grip range defines the permitted combined thickness of the connected materials.
The selected rivet must accommodate the complete material stack-up.
Relevant factors include:
Minimum panel thickness
Maximum panel thickness
Intermediate layers
Manufacturing tolerances
Coatings
Rivet body length
Blind-side formation
An incorrect grip range may prevent proper setting and reduce joint integrity.
Engineering Solution 12 — Hole Diameter and Sealing Reliability
Mounting-hole dimensions affect both mechanical performance and sealing behavior.
Engineers should verify:
Minimum hole diameter
Maximum hole diameter
Hole roundness
Hole alignment
Burr condition
Panel deformation
Surface contamination
Countersink quality
Oversized, cracked or damaged holes should not be accepted unless specifically approved by the responsible engineer.
A closed-end rivet cannot compensate for every hole defect.
Engineering Solution 13 — Shear Strength
Shear loading acts primarily across the rivet and joint interface.
Shear capacity depends on:
Rivet diameter
Rivet body material
Mandrel material
Rivet geometry
Retained mandrel position
Grip thickness
Hole diameter
Installation quality
The complete joint may fail through fastener shear, panel bearing or other mechanisms.
Actual shear values must be verified for the selected product.
Engineering Solution 14 — Tensile Strength and Pull-Through
Tensile loading acts primarily along the fastener axis.
Relevant failure mechanisms include:
Rivet body fracture
Mandrel retention failure
Head-side pull-through
Blind-side pull-through
Panel deformation
Local material failure
Countersunk head geometry can influence head-side pull-through resistance.
The remaining panel thickness beneath the countersink must be considered.
No numerical tensile performance is claimed without verified data.
Engineering Solution 15 — Mandrel Retention
The original product description refers to a retained mandrel.
However, retained mandrel behavior depends on the specific rivet design.
A closed-end body does not automatically establish a particular mechanical locking mechanism.
Engineers should confirm:
Mandrel break position
Retained mandrel geometry
Retention mechanism
Inspection requirements
Tool compatibility
Relevant vibration requirements
No guarantee that the mandrel can never loosen is made without supporting qualification.
Engineering Solution 16 — Installation Tooling and Nosepiece Selection
A compatible blind riveting tool and nosepiece are required.
Tool selection should consider:
Rivet diameter
Mandrel diameter
Required pulling force
Tool stroke
Nosepiece geometry
Head access
Production cycle time
Mandrel collection
Installation monitoring
The tool must be suitable for the selected stainless steel rivet configuration.
Typical Installation Procedure
Confirm the approved rivet part number.
Verify the rivet body and mandrel material specifications.
Confirm the combined material thickness.
Select the correct grip range.
Prepare the mounting hole.
Machine or form the approved 120° countersink.
Remove burrs and inspect the seating surface.
Select the compatible riveting tool and nosepiece.
Insert the rivet from the accessible side.
Confirm that the countersunk head seats correctly.
Pull the mandrel to form the blind-side retaining portion.
Complete the mandrel break.
Inspect the head position and installed joint.
Perform sealing verification where required.
Confirm acceptance against the approved engineering specification.
Engineering Solution 17 — Sealing Materials and Additional Joint Protection
Some applications may require additional sealing measures around the riveted joint.
These may include approved sealants, gaskets or other assembly-level sealing features.
Any additional material must be compatible with:
Stainless steel
Mating panel materials
Coatings
Operating temperature
Moisture exposure
Chemicals
Assembly process
The use of sealant should not be assumed necessary or acceptable for every application.
Engineering Solution 18 — Metric and Inch Diameter Reference
Common nominal blind rivet diameter references include:
| Metric Diameter | Approximate Inch Reference |
|---|---|
| 3.2 mm | 1/8 in |
| 4.0 mm | 5/32 in |
| 4.8 mm | 3/16 in |
| 6.4 mm | 1/4 in |
These are general dimensional references, not a confirmed list of available sizes for this JUXIN product.
Actual metric and inch-designated rivets must be checked for dimensions, tolerances, grip ranges, countersink geometry and tooling compatibility before substitution.
Industrial Applications and Engineering Solutions
120° countersunk closed-end stainless steel blind rivets may be evaluated for OEM assemblies requiring flush-head fastening, one-sided access and controlled leakage paths.
The following are potential engineering applications, not product-specific certifications or approvals.
1. Industrial Sheet-Metal Enclosures
Industrial enclosures may use stainless steel covers, protective panels and auxiliary brackets.
Closed-end countersunk rivets may be considered where a flush surface and reduced leakage through the fastener body are desirable.
Joint sealing and mechanical performance must be verified.
2. Electrical Equipment Cabinets
Electrical cabinets may require flush-head fastening for covers, brackets and protective housings.
Closed-end stainless steel rivets may be evaluated for suitable mechanical connections.
Electrical bonding, moisture protection and equipment qualification requirements must be considered.
3. AI Data Center Equipment
AI data center infrastructure may incorporate power cabinets, cooling equipment housings and protective sheet-metal panels.
Closed-end countersunk rivets may be considered for suitable enclosure connections requiring limited head projection.
Condensation, corrosion, electrical requirements and serviceability must be evaluated.
4. Liquid Cooling Equipment Housings
Liquid cooling equipment may contain protective covers, auxiliary panels and external housings.
Closed-end rivets may be evaluated for suitable non-pressure-boundary connections.
They should not be assumed suitable for coolant pressure containment or leak-critical fluid passages.
5. Telecommunications Equipment
Telecommunications equipment may use outdoor stainless steel cabinets, protective covers and auxiliary brackets.
Closed-end countersunk rivets may be considered where surface clearance and moisture exposure are important.
Environmental sealing and corrosion requirements must be verified.
6. HVAC and Industrial Ventilation
HVAC equipment may include stainless steel housings, protective covers and auxiliary brackets.
Closed-end countersunk rivets may be evaluated for suitable permanent connections.
Condensation, vibration and maintenance requirements must be considered.
7. Commercial Vehicle Manufacturing
Commercial vehicles may incorporate stainless steel equipment housings, panels and auxiliary brackets.
Closed-end countersunk rivets may be considered where flush mounting and reduced moisture passage are useful.
Vibration, fatigue, corrosion and joint strength require validation.
8. Trailer and Container Equipment
Trailers and containers may use protective panels, equipment compartments and auxiliary metal structures.
Closed-end rivets may be evaluated for suitable enclosure connections.
Primary structural connections and required weather-sealing performance need separate engineering approval.
9. Automotive OEM Components
Automotive assemblies may require flush-head fastening of selected covers, brackets and metal panels.
Closed-end stainless steel rivets may be considered where approved by the product engineering specification.
Mechanical, corrosion and fatigue requirements must be satisfied.
10. Food Processing Equipment
Food-processing equipment may use stainless steel covers, guards and auxiliary housings.
Closed-end countersunk rivets may be evaluated for suitable non-product-contact mechanical connections.
Crevice corrosion, cleaning chemicals and hygienic design must be assessed.
No food-contact or hygienic certification is implied.
11. Medical Equipment Housings
Medical equipment may incorporate stainless steel covers, panels and protective enclosures.
Closed-end countersunk rivets may be considered for approved non-patient-contact assemblies.
Cleaning, corrosion, traceability and regulatory requirements must be reviewed.
12. Semiconductor Equipment
Semiconductor equipment may use stainless steel protective panels, cabinets and auxiliary housings.
Closed-end rivets may be considered for approved non-process-critical connections.
Cleanliness, particle generation, corrosion and maintenance requirements must be evaluated.
13. Energy Storage Equipment
Energy storage equipment may include stainless steel cabinets, protective panels and auxiliary brackets.
Closed-end countersunk rivets may be evaluated for suitable mechanical connections.
Electrical isolation, thermal conditions, vibration and environmental sealing require assessment.
14. Power Distribution Equipment
Power distribution equipment may use stainless steel cabinets, auxiliary brackets and protective covers.
Flush-head closed-end rivets may be considered where the approved design requires permanent one-sided fastening.
Electrical clearances, grounding and moisture protection must be reviewed.
15. Marine Auxiliary Equipment
Marine equipment may use stainless steel covers, protective housings and brackets.
Closed-end countersunk rivets require evaluation of the actual stainless steel grades, chloride exposure and crevice corrosion risks.
No seawater pressure-boundary or marine structural qualification is implied.
16. Industrial Machinery
Industrial machinery may use protective guards, covers and auxiliary sheet-metal housings.
Closed-end stainless steel rivets may be considered where permanent flush-head fastening is appropriate.
Vibration, impact, corrosion and serviceability must be reviewed.
17. Rail Transit Auxiliary Equipment
Rail equipment may contain stainless steel enclosures, protective panels and equipment covers.
Closed-end countersunk rivets may be considered only where permitted by the approved project specification.
Vibration, fatigue, fire and smoke, traceability and other relevant requirements must be addressed.
18. Custom OEM Sheet-Metal Assemblies
Custom OEM manufacturers may require stainless steel closed-end blind rivets with specified head geometry, grip range and sealing requirements.
JUXIN FASTENERS can review customer drawings and technical specifications for suitable product configurations and quotation.
Application Selection Matrix
| Engineering Requirement | Selection Consideration |
|---|---|
| Flush mounting | Confirm 120° countersink geometry |
| Closed-end construction | Verify sealed rivet body |
| Stainless steel body | Confirm exact 300-series grade |
| Stainless steel mandrel | Confirm exact mandrel grade |
| Moisture exposure | Evaluate complete joint sealing |
| Air leakage requirement | Define test pressure and leakage limit |
| Defined panel thickness | Verify grip range |
| Thin sheet metal | Check remaining countersink wall thickness |
| High shear loading | Verify actual shear data |
| High tensile loading | Verify actual tensile data |
| Vibration exposure | Validate complete joint performance |
| Outdoor equipment | Evaluate corrosion resistance |
| High-volume production | Validate tooling and process controls |
| Pressure-boundary application | Require separate engineering qualification |
Production Engineering and Quality Control
For production managers and manufacturing engineers, repeatable closed-end countersunk riveting requires control of both the rivet and the prepared mounting hole.
Important production characteristics include:
Approved rivet part number
Rivet body stainless steel grade
Mandrel stainless steel grade
Rivet diameter and length
Countersunk head dimensions
Countersink angle
Countersink depth
Mounting-hole diameter
Grip range
Panel thickness
Surface condition
Tool and nosepiece identification
Installation force and stroke, where specified
Head seating
Blind-side formation
Mandrel break condition
Leakage testing, where required
Inspection sampling
Material traceability
Production trials should be completed where required before full-volume manufacturing.
Common Installation Problems and Engineering Checks
| Potential Problem | Engineering Check |
|---|---|
| Protruding countersunk head | Check countersink depth and head geometry |
| Head seated too deeply | Review countersink dimensions and panel thickness |
| Uneven head seating | Check countersink angle and surface condition |
| Loose joint | Verify grip range and material stack-up |
| Incomplete blind-side formation | Check rivet length and tool stroke |
| Water leakage around rivet | Review hole fit, head seating and joint sealing |
| Air leakage | Evaluate complete assembly and test method |
| Panel pull-through | Check panel thickness and joint loading |
| Unexpected mandrel movement | Verify product design and installation |
| Insufficient mechanical strength | Check verified product data and joint design |
| Corrosion | Review stainless steel grades and environment |
| Production variation | Inspect tooling and process controls |
International Standards and Technical Qualification
Closed-end countersunk blind rivets may be specified using applicable product standards, manufacturer specifications and customer-approved engineering drawings.
The exact material combination, head angle, rivet construction and dimensional requirements determine which standard may apply.
A standard covering an open-end rivet or protruding-head rivet must not automatically be applied to a closed-end 120° countersunk product.
Technical qualification should establish:
Rivet body material grade
Mandrel material grade
Head geometry
Countersink angle
Rivet dimensions and tolerances
Grip range
Mounting-hole requirements
Shear and tensile performance
Mandrel retention
Installation tooling
Corrosion requirements
Joint sealing requirements
Inspection criteria
Where ISO, DIN, EN, ASTM, SAE, IFI or customer-specific specifications apply, conformity must be verified against the actual product.
No unverified standard conformity or certification is claimed.
OEM Procurement and Supplier Development
For purchasing managers, supplier development engineers and supply chain managers, closed-end stainless steel blind rivets should be sourced using complete engineering requirements.
A technical RFQ should identify:
Approved product drawing
Rivet body stainless steel grade
Mandrel stainless steel grade
Rivet diameter and body length
120° countersunk head dimensions
Countersink depth and diameter
Minimum and maximum grip thickness
Mounting-hole diameter and tolerance
Required shear and tensile loads
Sealing requirements
Corrosion and environmental conditions
Installation tooling
Inspection and traceability
Packaging
Expected annual demand
The total installed cost should consider countersink preparation, tooling, assembly time, inspection, sealing verification and quality consistency rather than unit price alone.
Frequently Asked Questions
What is a 120° countersunk closed-end stainless steel blind rivet?
It is a stainless steel break-mandrel blind rivet with a closed blind-end body and a 120-degree countersunk head, designed for one-sided installation.
What is the difference between closed-end and open-end blind rivets?
Closed-end rivets use a sealed blind-end body to reduce potential leakage through the fastener, while open-end rivets have a different body construction.
Does a closed-end rivet create a watertight joint?
Not automatically. The complete joint must be designed and tested for the required sealing conditions.
Why use a 120° countersunk head?
It allows a flush or near-flush installation when the mating panel has a correctly prepared 120° countersink.
Can a 120° countersunk rivet replace a dome head rivet?
Only after engineering review of the head geometry, countersink, panel thickness and mechanical requirements.
Are these rivets made from 18-8 stainless steel?
The original product information specifies a 300-series stainless steel body and stainless steel mandrel. Exact grades must be confirmed.
Are the body and mandrel the same stainless steel grade?
Not necessarily. The body and mandrel grades should be specified separately.
Are these rivets corrosion-proof?
No. Corrosion resistance depends on the actual stainless steel grades and service environment.
Can these rivets be used in pressure vessels?
Not without separate engineering qualification for the pressure-boundary application.
Are these rivets suitable for vibration?
Suitability depends on the complete joint, mandrel retention and verified fatigue performance.
Can JUXIN review custom closed-end countersunk rivet requirements?
Customer drawings, dimensions, material specifications and sealing requirements can be submitted for technical review and quotation.
Request a 120° Countersunk Closed-End Stainless Steel Blind Rivet OEM Quotation
JUXIN FASTENERS supplies industrial blind riveting solutions for OEM manufacturing, sheet-metal fabrication and bulk purchasing projects.
For technical review and quotation, please provide:
2D engineering drawing or 3D CAD model
Rivet body stainless steel grade
Mandrel stainless steel grade
Rivet diameter and body length
120° countersunk head dimensions
Countersink diameter and depth
Minimum and maximum grip thickness
Mounting-hole diameter and tolerance
Required shear and tensile performance
Sealing or leakage requirements
Corrosion and environmental conditions
Installation tooling and nosepiece requirements
Inspection and traceability requirements
Expected order quantity
Annual demand forecast
Packaging specifications
Target delivery schedule
Email: info@juxinfasteners.com
Website: https://www.juxinfasteners.com/
JUXIN FASTENERS — 120° Countersunk Closed-End Stainless Steel Blind Rivets for Global OEM Manufacturing.
Product Packaging
Packaging Standard
At Juxin Fasteners, we apply standardized export packaging to ensure product protection, traceability, and compliance with international logistics requirements.
1. Standard Export Packaging
Unless otherwise specified, all products will be packed according to our factory standard export packaging, which includes:
Moisture-resistant inner protection
Poly bag or small box packing as required
Reinforced export cartons
Clear labeling with part number, specification, batch number, and quantity
Palletizing for sea or air shipment when necessary
Our standard packaging is designed to ensure safe transportation, efficient warehousing, and long-distance international shipping.
2. Customized Packaging Options
We also provide customized packaging solutions according to customer requirements, including but not limited to:
Private labeling
Customized barcodes
Specific carton dimensions
Retail packaging
Special pallet configuration
Customer-specific marking and identification
So that you know, customized packaging may involve additional costs and extended lead time depending on the complexity of the requirements.
3. Compliance & Quality Assurance
All packaging processes are controlled under our ISO 9001 quality management system to ensure consistency, traceability, and product integrity throughout the supply chain.
Product Pictures


Contact Us
Tel.:
+86 020 8621 0320
+86 020 3121 6067
E-mail:
Technical Support:
Navigation
SEND INQUIREY